Testing the 814 in triode mode
Worried about the G2 maximum voltage limit as per datasheet in class B, I decided to test the 814 carefully. So carefully that had a bit of smoke and fireworks (but not inside the valve)
Paul Leclercq suggested adding the grid resistors in G2 and G3 and do some baby steps whilst testing this lady.
Here is the test rig used:

The valve is astonishingly linear. At 600V anode voltage and 50mA quiescent current the valve only produced THD=0.01% at 15Vrms output!
Internal pannel meter wasn’t disconnected and apparently didn’t survive the 600V exposure so blew up and a domino effect provided some interesting fireworks inside my bench supply (series MOSFET regulator) 🙂
Evidently something went wrong with an unexpected short to ground, couldn’t be bothered with doing some proper root cause analysis so shut everything down and brewed myself a cup of tea….