{"id":8267,"date":"2020-02-19T13:16:35","date_gmt":"2020-02-19T13:16:35","guid":{"rendered":"http:\/\/www.bartola.co.uk\/valves\/?p=8267"},"modified":"2020-02-19T13:16:35","modified_gmt":"2020-02-19T13:16:35","slug":"300b-filament-supply","status":"publish","type":"post","link":"https:\/\/www.bartola.co.uk\/valves\/2020\/02\/19\/300b-filament-supply\/","title":{"rendered":"300B filament supply"},"content":{"rendered":"<p>In the process of rebuilding my old 300B amplifier, I decided to make a new filament power supply. It all came up around the components I had at hand, so it could&#8217;ve been improved but that meant extra cost:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/300B-filament-supply-v01-scaled.jpg\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"8268\" data-permalink=\"https:\/\/www.bartola.co.uk\/valves\/2020\/02\/19\/300b-filament-supply\/300b-filament-supply-v01\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/300B-filament-supply-v01-scaled.jpg?fit=2560%2C759&amp;ssl=1\" data-orig-size=\"2560,759\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"300B filament supply v01\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/300B-filament-supply-v01-scaled.jpg?fit=840%2C249&amp;ssl=1\" class=\"size-large wp-image-8268 aligncenter\" src=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/300B-filament-supply-v01-1024x304.jpg?resize=840%2C249\" alt=\"\" width=\"840\" height=\"249\" srcset=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/300B-filament-supply-v01-scaled.jpg?resize=1024%2C304&amp;ssl=1 1024w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/300B-filament-supply-v01-scaled.jpg?resize=300%2C89&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/300B-filament-supply-v01-scaled.jpg?resize=768%2C228&amp;ssl=1 768w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/300B-filament-supply-v01-scaled.jpg?resize=1536%2C456&amp;ssl=1 1536w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/300B-filament-supply-v01-scaled.jpg?resize=2048%2C607&amp;ssl=1 2048w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/300B-filament-supply-v01-scaled.jpg?resize=1200%2C356&amp;ssl=1 1200w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/300B-filament-supply-v01-scaled.jpg?w=1680&amp;ssl=1 1680w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/300B-filament-supply-v01-scaled.jpg?w=2520&amp;ssl=1 2520w\" sizes=\"auto, (max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 1362px) 62vw, 840px\" \/><\/a>I have a pair of custom-made JMS transformers with multi-taps secondaries. This helps me tweaking the right output voltage. Anyhow, any 15V transformer would do. Perhaps you want 14V to ensure you don&#8217;t dissipate too much on the filament regulators (e.g. Rod Coleman regulators)<\/p>\n<p>I used my flexible LT supply PCB which allowed me to build this in less than 1 hour. I also used some existing chokes made in the UK by &#8220;Spirit&#8221; which are ok for this purpose. The Lundahls are in use, so can&#8217;t reuse them:<\/p>\n<figure id=\"attachment_8269\" aria-describedby=\"caption-attachment-8269\" style=\"width: 840px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/IMG_1236.jpg\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"8269\" data-permalink=\"https:\/\/www.bartola.co.uk\/valves\/2020\/02\/19\/300b-filament-supply\/img_1236-2\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/IMG_1236.jpg?fit=1677%2C1467&amp;ssl=1\" data-orig-size=\"1677,1467\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;1.8&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;iPhone 8&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1582115408&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;3.99&quot;,&quot;iso&quot;:&quot;80&quot;,&quot;shutter_speed&quot;:&quot;0.066666666666667&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"IMG_1236\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;300B filament board ready&lt;\/p&gt;\n\" data-large-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/IMG_1236.jpg?fit=840%2C735&amp;ssl=1\" class=\"size-large wp-image-8269\" src=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/IMG_1236-1024x896.jpg?resize=840%2C735\" alt=\"\" width=\"840\" height=\"735\" srcset=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/IMG_1236.jpg?resize=1024%2C896&amp;ssl=1 1024w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/IMG_1236.jpg?resize=300%2C262&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/IMG_1236.jpg?resize=768%2C672&amp;ssl=1 768w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/IMG_1236.jpg?resize=1536%2C1344&amp;ssl=1 1536w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/IMG_1236.jpg?resize=1200%2C1050&amp;ssl=1 1200w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2020\/02\/IMG_1236.jpg?w=1677&amp;ssl=1 1677w\" sizes=\"auto, (max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 1362px) 62vw, 840px\" \/><\/a><figcaption id=\"caption-attachment-8269\" class=\"wp-caption-text\">300B filament board ready<\/figcaption><\/figure>\n<p>I used some SOT-128-2 schottky rectifiers but any other should work as well. Resistors are wirewound and the CMR choke is what I had in stock as well. A simple 15mH\/3A should do fine.<\/p>\n<p>The output measured well at 9V with a 6R load which dragged 1.5A. A bit more than the 300B but should be a good indication of performance. Also ripple level is good at 2.5mVrms. The rest will be cleaned up by the regulator itself \ud83d\ude42<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In the process of rebuilding my old 300B amplifier, I decided to make a new filament power supply. It all came up around the components I had at hand, so it could&#8217;ve been improved but that meant extra cost: I have a pair of custom-made JMS transformers with multi-taps secondaries. This helps me tweaking the &hellip; <a href=\"https:\/\/www.bartola.co.uk\/valves\/2020\/02\/19\/300b-filament-supply\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;300B filament supply&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2},"jetpack_post_was_ever_published":false},"categories":[673,1179],"tags":[610,1307,894,1308,275,990],"class_list":["post-8267","post","type-post","status-publish","format-standard","hentry","category-300b-amp","category-pcb","tag-300b","tag-300b-filament-supply","tag-bartola-pcb","tag-lt-supply-pcb","tag-rod-coleman","tag-rod-coleman-filament-regulator"],"jetpack_publicize_connections":[],"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/p2r2tK-29l","jetpack_likes_enabled":true,"jetpack-related-posts":[],"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts\/8267","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/comments?post=8267"}],"version-history":[{"count":1,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts\/8267\/revisions"}],"predecessor-version":[{"id":8270,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts\/8267\/revisions\/8270"}],"wp:attachment":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/media?parent=8267"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/categories?post=8267"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/tags?post=8267"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}