{"id":7786,"date":"2019-03-02T12:35:33","date_gmt":"2019-03-02T12:35:33","guid":{"rendered":"http:\/\/www.bartola.co.uk\/valves\/?p=7786"},"modified":"2019-03-02T12:35:33","modified_gmt":"2019-03-02T12:35:33","slug":"tail-ccs-pcb-test","status":"publish","type":"post","link":"https:\/\/www.bartola.co.uk\/valves\/2019\/03\/02\/tail-ccs-pcb-test\/","title":{"rendered":"Tail CCS PCB test"},"content":{"rendered":"<p>A belated test of this simple, yet effective PCB. I made it as small as possible, however in order to provide flexible connections, it&#8217;s actually double the size. Still at 4 x 4 cm is small enough.<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2027.jpg\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"7787\" data-permalink=\"https:\/\/www.bartola.co.uk\/valves\/2019\/03\/02\/tail-ccs-pcb-test\/img_2027\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2027.jpg?fit=2330%2C3356&amp;ssl=1\" data-orig-size=\"2330,3356\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;1.8&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;iPhone 8&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1551528275&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;3.99&quot;,&quot;iso&quot;:&quot;50&quot;,&quot;shutter_speed&quot;:&quot;0.0083333333333333&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"IMG_2027\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2027.jpg?fit=711%2C1024&amp;ssl=1\" class=\"size-large wp-image-7787 aligncenter\" src=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2027-711x1024.jpg?resize=711%2C1024\" alt=\"\" width=\"711\" height=\"1024\" srcset=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2027.jpg?resize=711%2C1024&amp;ssl=1 711w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2027.jpg?resize=208%2C300&amp;ssl=1 208w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2027.jpg?resize=768%2C1106&amp;ssl=1 768w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2027.jpg?resize=1200%2C1728&amp;ssl=1 1200w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2027.jpg?w=1680&amp;ssl=1 1680w\" sizes=\"auto, (max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><\/a><\/p>\n<p><!--more--><\/p>\n<p>You can solder the 2mm PCB connector or alternatively you can use the 2-pole block connectors. It provides the full functionality for a cathode follower, however you can bypass some elements when using it as a tail CCS for a differential pair for example:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/Tail-CCS-v04.jpg\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"7788\" data-permalink=\"https:\/\/www.bartola.co.uk\/valves\/2019\/03\/02\/tail-ccs-pcb-test\/tail-ccs-v04\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/Tail-CCS-v04.jpg?fit=741%2C539&amp;ssl=1\" data-orig-size=\"741,539\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"Tail CCS v04\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/Tail-CCS-v04.jpg?fit=741%2C539&amp;ssl=1\" class=\"size-full wp-image-7788 aligncenter\" src=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/Tail-CCS-v04.jpg?resize=741%2C539\" alt=\"\" width=\"741\" height=\"539\" srcset=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/Tail-CCS-v04.jpg?w=741&amp;ssl=1 741w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/Tail-CCS-v04.jpg?resize=300%2C218&amp;ssl=1 300w\" sizes=\"auto, (max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><\/a>You can use either R2 or P1 to set the CCS current. T1 is any high hFE NPN you have at hand. I use BC547C because I have plenty. For the top device you have 2 options in order to accommodate different power requirements. I use the <a href=\"https:\/\/www.mouser.com\/ds\/2\/149\/KSC3503-90028.pdf\">2SC3503<\/a>\u00a0as it has low capacitance and works up to 300V with 7W of PD. T2 is for TO-126 devices and T3 is for TO-92 ones. You can use a plethora of different NPNs here depending your voltage requirements.<\/p>\n<p>If you want to self-bias the cathode follower you have R3 and R4. If not required, R3 should be replaced with a wire jumper and R4 ignored.<\/p>\n<p>R1 set the current for the LED voltage reference array for both T2\/3 and T1.<\/p>\n<p>R11 is a build out resistor. Again if not needed, can be\u00a0replaced with a wire jumper.<\/p>\n<h2>Cathode Follower Test<\/h2>\n<p>As per my previous test for the <a href=\"http:\/\/www.bartola.co.uk\/valves\/2019\/02\/08\/bootstrapped-cf-slcf-pcb-tests\/\">SLCF board<\/a>, I used the 6J52P\/6Z52P high-gm pentode in triode mode. Here is what I breadboarded quickly this morning:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-tail-CCS-test.jpg\"><br \/>\n<img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"7790\" data-permalink=\"https:\/\/www.bartola.co.uk\/valves\/2019\/03\/02\/tail-ccs-pcb-test\/6j52p-tail-ccs-test\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-tail-CCS-test.jpg?fit=841%2C760&amp;ssl=1\" data-orig-size=\"841,760\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"6J52P tail CCS test\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-tail-CCS-test.jpg?fit=840%2C759&amp;ssl=1\" class=\"size-full wp-image-7790 aligncenter\" src=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-tail-CCS-test.jpg?resize=840%2C759\" alt=\"\" width=\"840\" height=\"759\" srcset=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-tail-CCS-test.jpg?w=841&amp;ssl=1 841w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-tail-CCS-test.jpg?resize=300%2C271&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-tail-CCS-test.jpg?resize=768%2C694&amp;ssl=1 768w\" sizes=\"auto, (max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 1362px) 62vw, 840px\" \/><\/a><\/p>\n<p>Being lazy I didn&#8217;t play much with the operating point. I left the CCS set to 15mA, not 20mA as per previous example. The results of this stage are impressive. Here is the neat frequency response:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-CF-test-01.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"7791\" data-permalink=\"https:\/\/www.bartola.co.uk\/valves\/2019\/03\/02\/tail-ccs-pcb-test\/6j52p-cf-test-01\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-CF-test-01.png?fit=1060%2C644&amp;ssl=1\" data-orig-size=\"1060,644\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"6J52P CF test 01\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-CF-test-01.png?fit=840%2C510&amp;ssl=1\" class=\"size-large wp-image-7791 aligncenter\" src=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-CF-test-01-1024x622.png?resize=840%2C510\" alt=\"\" width=\"840\" height=\"510\" srcset=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-CF-test-01.png?resize=1024%2C622&amp;ssl=1 1024w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-CF-test-01.png?resize=300%2C182&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-CF-test-01.png?resize=768%2C467&amp;ssl=1 768w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-CF-test-01.png?w=1060&amp;ssl=1 1060w\" sizes=\"auto, (max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 1362px) 62vw, 840px\" \/><\/a><\/p>\n<p>The stage is flat up to 4.2Mhz. Also the distortion is extremely low. Here is an example of the harmonics at 3Vrms:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-CF-test-01-THD.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"7792\" data-permalink=\"https:\/\/www.bartola.co.uk\/valves\/2019\/03\/02\/tail-ccs-pcb-test\/6j52p-cf-test-01-thd\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-CF-test-01-THD.png?fit=1143%2C334&amp;ssl=1\" data-orig-size=\"1143,334\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"6J52P CF test 01 THD\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-CF-test-01-THD.png?fit=840%2C245&amp;ssl=1\" class=\"size-large wp-image-7792 aligncenter\" src=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-CF-test-01-THD-1024x299.png?resize=840%2C245\" alt=\"\" width=\"840\" height=\"245\" srcset=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-CF-test-01-THD.png?resize=1024%2C299&amp;ssl=1 1024w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-CF-test-01-THD.png?resize=300%2C88&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-CF-test-01-THD.png?resize=768%2C224&amp;ssl=1 768w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/6J52P-CF-test-01-THD.png?w=1143&amp;ssl=1 1143w\" sizes=\"auto, (max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 1362px) 62vw, 840px\" \/><\/a><\/p>\n<p>You can see the level of harmonics is very low with a THD of 0.003%. It&#8217;s just down there.<\/p>\n<p>Here&#8217;s a picture of the rat nest!<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2025.jpg\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"7793\" data-permalink=\"https:\/\/www.bartola.co.uk\/valves\/2019\/03\/02\/tail-ccs-pcb-test\/img_2025\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2025-e1551529866135.jpg?fit=3024%2C4032&amp;ssl=1\" data-orig-size=\"3024,4032\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;1.8&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;iPhone 8&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1551528193&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;3.99&quot;,&quot;iso&quot;:&quot;40&quot;,&quot;shutter_speed&quot;:&quot;0.033333333333333&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;6&quot;}\" data-image-title=\"IMG_2025\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2025-e1551529866135.jpg?fit=768%2C1024&amp;ssl=1\" class=\"wp-image-7793 size-large aligncenter\" src=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2025-e1551529866135-768x1024.jpg?resize=768%2C1024\" alt=\"\" width=\"768\" height=\"1024\" srcset=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2025-e1551529866135.jpg?resize=768%2C1024&amp;ssl=1 768w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2025-e1551529866135.jpg?resize=225%2C300&amp;ssl=1 225w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2025-e1551529866135.jpg?resize=1200%2C1600&amp;ssl=1 1200w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2025-e1551529866135.jpg?w=1680&amp;ssl=1 1680w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2019\/03\/IMG_2025-e1551529866135.jpg?w=2520&amp;ssl=1 2520w\" sizes=\"auto, (max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><\/a><\/p>\n<p>A bit less HF response due to the lack of bootstrapping in the anode and similar distortion performance to the SLCF in terms of distortion. Both stages are operating at different bias levels so can&#8217;t compare apples to apples.<\/p>\n<p>PCB prototype was a success&#8230;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>A belated test of this simple, yet effective PCB. I made it as small as possible, however in order to provide flexible connections, it&#8217;s actually double the size. Still at 4 x 4 cm is small enough.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2}},"categories":[153,1179,67,5],"tags":[772,1207,1143,625,894,791,1209,57,1087,1208,800,1210,1211],"class_list":["post-7786","post","type-post","status-publish","format-standard","hentry","category-driver","category-pcb","category-thd","category-valves","tag-6j52p","tag-6j52p-cathode-follower","tag-6z52p","tag-bartola","tag-bartola-pcb","tag-cathode-follower","tag-cathode-follower-pcb","tag-ccs","tag-ccs-pcb","tag-cf","tag-slcf","tag-tail-ccs","tag-tail-ccs-pcb"],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/p2r2tK-21A","jetpack_likes_enabled":true,"jetpack-related-posts":[],"_links":{"self":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts\/7786","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/comments?post=7786"}],"version-history":[{"count":2,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts\/7786\/revisions"}],"predecessor-version":[{"id":7794,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts\/7786\/revisions\/7794"}],"wp:attachment":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/media?parent=7786"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/categories?post=7786"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/tags?post=7786"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}