{"id":5337,"date":"2016-02-28T19:03:01","date_gmt":"2016-02-28T19:03:01","guid":{"rendered":"http:\/\/www.bartola.co.uk\/valves\/?p=5337"},"modified":"2016-02-28T19:03:01","modified_gmt":"2016-02-28T19:03:01","slug":"sweep-buffer","status":"publish","type":"post","link":"https:\/\/www.bartola.co.uk\/valves\/2016\/02\/28\/sweep-buffer\/","title":{"rendered":"Sweep buffer"},"content":{"rendered":"<p>I&#8217;ve been using my sound card and Pete Millett&#8217;s interface for testing. However, the limitation on high frequency response is due to the sound card. A cheap, but yet effective option, is to use the Chinese digital oscilloscope <a href=\"http:\/\/instrustar.com\/upload\/user%20guide\/ISDS2062A(B)%20User%20Guide.pdf\">Instrustar ISDS2062B<\/a> which comes with built-in DDS signal generator with sweep capability. With this little piece of technology, you can sweep up to 10Mhz. The resolution is 12bit, not great for FFT but good enough for a FR analysis. For frequencies above 20kHz, you can use this device to look into things. For FFT and THD analysis, I will keep using the sound card and audio interface as usual.<\/p>\n<p>When I test the device, I found that the DDS output didn&#8217;t have the stones to drive loads at HF. Therefore I went back to my workshop and built the following sweep driver. This was based on the great <a href=\"http:\/\/www.analog.com\/media\/en\/technical-documentation\/data-sheets\/SSM2019.pdf\">SSM2019<\/a> that my friend Mogens sent me:<\/p>\n<figure id=\"attachment_5339\" aria-describedby=\"caption-attachment-5339\" style=\"width: 584px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-buffer.jpg\" rel=\"attachment wp-att-5339\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"5339\" data-permalink=\"https:\/\/www.bartola.co.uk\/valves\/2016\/02\/28\/sweep-buffer\/ssm2019-sweep-buffer\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-buffer.jpg?fit=1598%2C992&amp;ssl=1\" data-orig-size=\"1598,992\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;2.4&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;iPad Air 2&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1456675098&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;3.3&quot;,&quot;iso&quot;:&quot;32&quot;,&quot;shutter_speed&quot;:&quot;0.03030303030303&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"SSM2019 sweep buffer\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;Sweep buffer based on SSM2019&lt;\/p&gt;\n\" data-large-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-buffer.jpg?fit=840%2C522&amp;ssl=1\" class=\"size-large wp-image-5339\" src=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-buffer-1024x636.jpg?resize=584%2C363\" alt=\"Sweep buffer based on SSM2019\" width=\"584\" height=\"363\" srcset=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-buffer.jpg?resize=1024%2C636&amp;ssl=1 1024w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-buffer.jpg?resize=300%2C186&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-buffer.jpg?resize=768%2C477&amp;ssl=1 768w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-buffer.jpg?resize=483%2C300&amp;ssl=1 483w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-buffer.jpg?w=1598&amp;ssl=1 1598w\" sizes=\"auto, (max-width: 584px) 85vw, 584px\" \/><\/a><figcaption id=\"caption-attachment-5339\" class=\"wp-caption-text\">Sweep buffer based on SSM2019<\/figcaption><\/figure>\n<p>The circuit is very simple. It&#8217;s operated from a pair of 9V batteries. So far, I&#8217;ve tested with the 20dB (actually 19dB gain due to 1k\u03a9 resistor at hand) and 0dB gain modes.<\/p>\n<p>The response is good enough for my purposes:<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-test.png\" rel=\"attachment wp-att-5340\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"5340\" data-permalink=\"https:\/\/www.bartola.co.uk\/valves\/2016\/02\/28\/sweep-buffer\/ssm2019-sweep-test\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-test.png?fit=1406%2C1161&amp;ssl=1\" data-orig-size=\"1406,1161\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"SSM2019 sweep test\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-test.png?fit=840%2C694&amp;ssl=1\" class=\"alignleft size-large wp-image-5340\" src=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-test-1024x846.png?resize=584%2C482\" alt=\"SSM2019 sweep test\" width=\"584\" height=\"482\" srcset=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-test.png?resize=1024%2C846&amp;ssl=1 1024w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-test.png?resize=300%2C248&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-test.png?resize=768%2C634&amp;ssl=1 768w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-test.png?resize=363%2C300&amp;ssl=1 363w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2016\/02\/SSM2019-sweep-test.png?w=1406&amp;ssl=1 1406w\" sizes=\"auto, (max-width: 584px) 85vw, 584px\" \/><\/a><\/p>\n<p>I can get 1.5Mhz @ 19dB or 3Mhz @ 0dB gain HF response which is great. I now need to test it again with a real load.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>I&#8217;ve been using my sound card and Pete Millett&#8217;s interface for testing. However, the limitation on high frequency response is due to the sound card. A cheap, but yet effective option, is to use the Chinese digital oscilloscope Instrustar ISDS2062B which comes with built-in DDS signal generator with sweep capability. With this little piece of &hellip; <a href=\"https:\/\/www.bartola.co.uk\/valves\/2016\/02\/28\/sweep-buffer\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Sweep buffer&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2}},"categories":[162,67,5],"tags":[877,878,881,879,880],"class_list":["post-5337","post","type-post","status-publish","format-standard","hentry","category-source","category-thd","category-valves","tag-fr","tag-fr-sweep-analysis","tag-frequency-response-test","tag-isds2062b","tag-ssm2019"],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/p2r2tK-1o5","jetpack_likes_enabled":true,"jetpack-related-posts":[],"_links":{"self":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts\/5337","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/comments?post=5337"}],"version-history":[{"count":2,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts\/5337\/revisions"}],"predecessor-version":[{"id":5341,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts\/5337\/revisions\/5341"}],"wp:attachment":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/media?parent=5337"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/categories?post=5337"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/tags?post=5337"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}