{"id":264,"date":"2012-06-16T18:42:08","date_gmt":"2012-06-16T18:42:08","guid":{"rendered":"http:\/\/www.bartola.co.uk\/valves\/?p=264"},"modified":"2012-06-16T18:42:08","modified_gmt":"2012-06-16T18:42:08","slug":"26-dht-thd-continued","status":"publish","type":"post","link":"https:\/\/www.bartola.co.uk\/valves\/2012\/06\/16\/26-dht-thd-continued\/","title":{"rendered":"26 DHT THD (continued)"},"content":{"rendered":"<h1>Looking for the optimal operating point<\/h1>\n<p>From an audiophile&#8217;s perspective, this is not the right approach to determine the optimal operating point. However, minimum distortion is a good indication of a good starting point for further refinement with your ears.<\/p>\n<p>I have used mostly the 26 DHT with filament bias in the following point:<\/p>\n<ul>\n<li>Vg=-10V<\/li>\n<li>Ia= 5.5mA<\/li>\n<\/ul>\n<figure id=\"attachment_265\" aria-describedby=\"caption-attachment-265\" style=\"width: 769px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2012\/06\/26-DHT-operating-point.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"265\" data-permalink=\"https:\/\/www.bartola.co.uk\/valves\/2012\/06\/16\/26-dht-thd-continued\/26-dht-operating-point\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2012\/06\/26-DHT-operating-point.png?fit=769%2C419&amp;ssl=1\" data-orig-size=\"769,419\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"26 DHT operating point\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;26 DHT THD as a function of Ia&lt;\/p&gt;\n\" data-large-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2012\/06\/26-DHT-operating-point.png?fit=769%2C419&amp;ssl=1\" class=\"size-full wp-image-265\" title=\"26 DHT operating point\" src=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2012\/06\/26-DHT-operating-point.png?resize=769%2C419\" alt=\"\" width=\"769\" height=\"419\" srcset=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2012\/06\/26-DHT-operating-point.png?w=769&amp;ssl=1 769w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2012\/06\/26-DHT-operating-point.png?resize=300%2C163&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2012\/06\/26-DHT-operating-point.png?resize=500%2C272&amp;ssl=1 500w\" sizes=\"auto, (max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><\/a><figcaption id=\"caption-attachment-265\" class=\"wp-caption-text\">26 DHT THD as a function of Ia<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>We can see in the diagram above that distortion decreases with the increase of anode current (lower ra and higher gm) and between 6-7mA it&#8217;s at its minimum of 0.04-0.05% at full output swing\/<\/p>\n<p>As posted previously, is well known that starving the filaments is a good approach to reduce microphony of the valve and THD as well. At the expense of increasing Ra.<\/p>\n<figure id=\"attachment_266\" aria-describedby=\"caption-attachment-266\" style=\"width: 769px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2012\/06\/26-DHT-operating-point-vs-filament-current.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"266\" data-permalink=\"https:\/\/www.bartola.co.uk\/valves\/2012\/06\/16\/26-dht-thd-continued\/26-dht-operating-point-vs-filament-current\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2012\/06\/26-DHT-operating-point-vs-filament-current.png?fit=769%2C419&amp;ssl=1\" data-orig-size=\"769,419\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"26 DHT operating point vs filament current\" data-image-description=\"\" data-image-caption=\"&lt;p&gt;THD impact of filament starvation&lt;\/p&gt;\n\" data-large-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2012\/06\/26-DHT-operating-point-vs-filament-current.png?fit=769%2C419&amp;ssl=1\" class=\"size-full wp-image-266\" title=\"26 DHT operating point vs filament current\" src=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2012\/06\/26-DHT-operating-point-vs-filament-current.png?resize=769%2C419\" alt=\"\" width=\"769\" height=\"419\" srcset=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2012\/06\/26-DHT-operating-point-vs-filament-current.png?w=769&amp;ssl=1 769w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2012\/06\/26-DHT-operating-point-vs-filament-current.png?resize=300%2C163&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2012\/06\/26-DHT-operating-point-vs-filament-current.png?resize=500%2C272&amp;ssl=1 500w\" sizes=\"auto, (max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><\/a><figcaption id=\"caption-attachment-266\" class=\"wp-caption-text\">THD impact of filament starvation<\/figcaption><\/figure>\n<p>From the picture above we can clearly see that a typical 26 running at 5.5mA and with filaments at the normal level (i.e. 1050mA) can achieve a reduction of distortion of about 0.02% by starving the filaments to 700mA (66%).<\/p>\n<p>I still need to test how this level of starvation will sound on my preamp, but is quite promising&#8230;(at least in theory)<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Looking for the optimal operating point From an audiophile&#8217;s perspective, this is not the right approach to determine the optimal operating point. However, minimum distortion is a good indication of a good starting point for further refinement with your ears. I have used mostly the 26 DHT with filament bias in the following point: Vg=-10V &hellip; <a href=\"https:\/\/www.bartola.co.uk\/valves\/2012\/06\/16\/26-dht-thd-continued\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;26 DHT THD (continued)&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2}},"categories":[12,67,38],"tags":[779,6,18,784,39],"class_list":["post-264","post","type-post","status-publish","format-standard","hentry","category-dht-valves","category-thd","category-valve-tester","tag-779","tag-dht","tag-pre-amp","tag-thd","tag-valve-tester-2"],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/p2r2tK-4g","jetpack_likes_enabled":true,"jetpack-related-posts":[],"_links":{"self":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts\/264","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/comments?post=264"}],"version-history":[{"count":1,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts\/264\/revisions"}],"predecessor-version":[{"id":267,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts\/264\/revisions\/267"}],"wp:attachment":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/media?parent=264"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/categories?post=264"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/tags?post=264"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}