{"id":1109,"date":"2013-01-20T19:01:15","date_gmt":"2013-01-20T19:01:15","guid":{"rendered":"http:\/\/www.bartola.co.uk\/valves\/?p=1109"},"modified":"2013-02-09T17:13:59","modified_gmt":"2013-02-09T17:13:59","slug":"4-65a-se-amp-testing-the-600v-raw-supply","status":"publish","type":"post","link":"https:\/\/www.bartola.co.uk\/valves\/2013\/01\/20\/4-65a-se-amp-testing-the-600v-raw-supply\/","title":{"rendered":"4-65a SE Amp: testing the 600V raw supply"},"content":{"rendered":"<h1>Burning the 6D22S damper valves<a href=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2013\/01\/20130120-190106.jpg\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"1108\" data-permalink=\"https:\/\/www.bartola.co.uk\/valves\/2013\/01\/20\/4-65a-se-amp-testing-the-600v-raw-supply\/20130120-190106-jpg\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2013\/01\/20130120-190106.jpg?fit=300%2C225&amp;ssl=1\" data-orig-size=\"300,225\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;2.4&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1358617565&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;4.28&quot;,&quot;iso&quot;:&quot;800&quot;,&quot;shutter_speed&quot;:&quot;0.066666666666667&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"20130120-190106.jpg\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2013\/01\/20130120-190106.jpg?fit=300%2C225&amp;ssl=1\" class=\"alignleft size-full wp-image-1108\" alt=\"20130120-190106.jpg\" src=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2013\/01\/20130120-190106.jpg?resize=300%2C225\" width=\"300\" height=\"225\" \/><\/a><\/h1>\n<p>After a failed initial test which caused the silicon and the damping series resistor of the hybrid bridge to blow up due to a gassy NOS 6D22S, I burned in the valves for 30min and tested the supply with a dummy load.<\/p>\n<p>Some few changes to the supply design included the replacement of the HV diodes with a series pair of 1200V@5A fast diodes. The filaments were referenced to cathode (+B) instead of ground to minimise Vhk and a snubber network formed of a pair of 100nF LCR 1.5kV capacitors across the input choke were added.<\/p>\n<h1>Supply under test<\/h1>\n<p>This is a hefty supply: massively heavy. The heaviest piece of iron I have built so far. Anyway, great decision to build this amp in a modular fashion, otherwise I would have need some mechanical aid for moving the stuff around and clearly my wife would have kicked me out of the house (she hasn&#8217;t seen this yet so the latter is yet to happen).<\/p>\n<p><a href=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2013\/01\/20130120-190032.jpg\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" class=\"alignnone \" alt=\"20130120-190032.jpg\" src=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2013\/01\/20130120-190032.jpg?resize=717%2C536\" width=\"717\" height=\"536\" \/><\/a><\/p>\n<p>The load resistor is a pair of 3k3 50W aluminium clad ones bolted to an aluminium piece which at the same time is held by a vice (thanks Rod for the suggestion). This provides sufficient mass and heat dissipation capacity (need about 120W).<\/p>\n<p>Initial tests were great, need to do some further ones.<\/p>\n<p>here is the diagram so far:<\/p>\n<address>Update 9th Feb 2013: Minor updates including rightsizing of the mains fuse and removal of earth switch as this supply will be used in floating mode<\/address>\n<address><a href=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2013\/01\/4-65a-600v-supply2.png\"><img data-recalc-dims=\"1\" loading=\"lazy\" decoding=\"async\" data-attachment-id=\"1193\" data-permalink=\"https:\/\/www.bartola.co.uk\/valves\/2013\/01\/20\/4-65a-se-amp-testing-the-600v-raw-supply\/4-65a-600v-supply-4\/\" data-orig-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2013\/01\/4-65a-600v-supply2.png?fit=1396%2C610&amp;ssl=1\" data-orig-size=\"1396,610\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;}\" data-image-title=\"4-65a 600v supply\" data-image-description=\"\" data-image-caption=\"\" data-large-file=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2013\/01\/4-65a-600v-supply2.png?fit=840%2C367&amp;ssl=1\" class=\"alignleft size-full wp-image-1193\" alt=\"4-65a 600v supply\" src=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2013\/01\/4-65a-600v-supply2.png?resize=840%2C367\" width=\"840\" height=\"367\" srcset=\"https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2013\/01\/4-65a-600v-supply2.png?w=1396&amp;ssl=1 1396w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2013\/01\/4-65a-600v-supply2.png?resize=300%2C131&amp;ssl=1 300w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2013\/01\/4-65a-600v-supply2.png?resize=1024%2C447&amp;ssl=1 1024w, https:\/\/i0.wp.com\/www.bartola.co.uk\/valves\/wp-content\/uploads\/2013\/01\/4-65a-600v-supply2.png?resize=500%2C218&amp;ssl=1 500w\" sizes=\"auto, (max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 1362px) 62vw, 840px\" \/><\/a><\/address>\n","protected":false},"excerpt":{"rendered":"<p>Burning the 6D22S damper valves After a failed initial test which caused the silicon and the damping series resistor of the hybrid bridge to blow up due to a gassy NOS 6D22S, I burned in the valves for 30min and tested the supply with a dummy load. Some few changes to the supply design included &hellip; <a href=\"https:\/\/www.bartola.co.uk\/valves\/2013\/01\/20\/4-65a-se-amp-testing-the-600v-raw-supply\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;4-65a SE Amp: testing the 600V raw supply&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2}},"categories":[150,152,5],"tags":[137,310,311],"class_list":["post-1109","post","type-post","status-publish","format-standard","hentry","category-4-65a-se-amplifier-2","category-power-supply","category-valves","tag-4-65a-se-amplifier","tag-600v-supply","tag-6d22s-supply"],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"","jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/p2r2tK-hT","jetpack_likes_enabled":true,"jetpack-related-posts":[],"_links":{"self":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts\/1109","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/comments?post=1109"}],"version-history":[{"count":4,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts\/1109\/revisions"}],"predecessor-version":[{"id":1195,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/posts\/1109\/revisions\/1195"}],"wp:attachment":[{"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/media?parent=1109"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/categories?post=1109"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bartola.co.uk\/valves\/wp-json\/wp\/v2\/tags?post=1109"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}